IVF SOLUTION BY LABOX
MBB-IVF
Class II biological safety cabinet
For IVF laboratories.
Protection of the product, operator and environment when handling tissues and cells. With motorised front sash, heated-surface and microscope integration options, and intelligent CR2000 control.
We assess the configuration and suitability for your specific application together with you.

Product, operator and environmental protection
Class II safety cabinet for applications requiring protection of both the material being handled and the workplace.
Motorised front sash
Monitored sash position and optical safety sensors in the sash travel area.
Working with a microscope
Heated surface and integration of selected, verified complete microscope assemblies.
Monitoring and service
Continuous parameter monitoring, alarms, remote diagnostics and operator assistance.
PROTECTION AND EASY OPERATION
Motorised front sash.
A carefully designed safety system.
SafeGlide™ provides motorised movement of the front sash with position monitoring. Cleaning modes facilitate access to the inner surface without tilting the sash.
- An optical safety barrier detects hands and objects in the sash travel area.
- With an integrated microscope, protection also accounts for the eyepieces.
- SafeScope Integration™ combines verified microscope integration with front-sash movement and safety features.
- Stainless-steel work zone with a watertight tray and an ergonomic front intake grille.

WORKING WITH TEMPERATURE-SENSITIVE MATERIAL
Heated work surface.
Verified microscope integration.
A 600 × 290 mm heated stainless-steel surface and heated quartz glass provide excellent temperature stability and uniformity, with rapid warm-up. CR2000 continuously measures and controls the temperature.
- Integration is available only for selected, verified complete microscope assemblies.
- Supported configurations based on Nikon SMZ1270, Olympus SZX2-ZB10 and Olympus SZX-ZB7.
- Compatibility covers the complete assembly, including stand, optics and illumination.
Request the relevant LABOX functional specification before ordering. Other configurations require prior consultation.
TECHNOLOGY UNDER CONTROL
From overview to detail.
Explore technologies that support precision work, intuitive operation and long-term equipment support of your MBB-IVF.
Advanced technologies.
Designed for everyday work.
Always a step ahead.
MBB-IVF combines product, operator and environmental protection with front-sash control, monitoring and connectivity.
- SMART CR2000: control of the cabinet, front sash and accessories.
- CTM: scheduling of the workstation and accessories.
- Monitoring, alarms and traceable changes in the audit trail.
- Remote access, image sharing and a central overview of multiple workstations.
Explore individual functions in the tabs. Available features depend on the equipment configuration and control system version.

Everything that matters.
On one screen.
The glove-compatible touchscreen displays workstation status and key operating parameters.
- Control of normal operating and reduced-airflow modes, front-sash position, lighting and installed accessories, including UV-C.
- Continuous monitoring of airflow velocity, HEPA filter pressure drop and temperatures, according to equipment.
- User permissions and operating limit settings.
- Operation from the panel and via the remote interface.
- Reduced-airflow mode is intended for breaks without handling material. Resume work only after returning to normal operating mode and allowing working conditions to stabilise.
Ready to work.
On your schedule.
The Central Timer Module (CTM) schedules operation of the workstation and its accessories.
- Scheduling of the fan, UV-C, heated surface and sockets according to installed equipment.
- Up to four time slots per day.
- Automatic start-up and shutdown according to the schedule.
- Notification before the scheduled end of operation.
The workstation can start before work begins, allowing time for working conditions to stabilise.
Key operating parameters at a glance.
Early warning of deviations.
Continuous monitoring of key parameters helps operators respond to abnormal conditions.
- Work-zone and exhaust airflow velocity, filter pressure drops and temperatures according to equipment.
- Visual and acoustic signals; voice messages for selected events.
- Alert and action limits for the main alarm conditions.
- Email alerts and push notifications when connected to the required network services.
- Operating data export to USB or by email, depending on configuration.
Traceable changes.
Clear records.
The audit trail records important changes to settings, operating events and alarms.
- Changes to temperature setpoints and other parameters.
- User access, including remote connections.
- Alarm and fault conditions.
- Service and qualification due-date notifications.
- Record export to USB or by email, depending on equipment.

The same interface.
Beyond the workstation panel.
The workstation can be operated and monitored from a computer, tablet or phone via the configured network connection.
- Access from Android, iOS and Windows.
- Remote diagnostics, settings and operator assistance.
- Firmware update support, subject to compatibility of the individual unit.
- Start the workstation in advance to prepare it for use.
Connection methods and access rights are configured to suit your laboratory infrastructure and policies.

EASYSHARE VIDEO STREAMING
What the embryologist sees,
the patient can see too.
Share the same image the embryologist is viewing on the display integrated into the rear wall of the workstation. The patient remains outside the embryology laboratory.
- Images from a microscope or camera shown on an external display in the consultation room.
- The clinician can explain what is on screen while viewing the same image with the patient.
- Also share images with colleagues or students on the local network.
Image streaming to the local network via RTSP. Image sources, display connections and feature availability are confirmed for the selected configuration.

Multiple workstations.
One shared overview.
The optional central monitoring software for Windows can monitor up to 50 CR2000-controlled workstations in one installation.
- Current equipment status, main operating parameters and alarms.
- An individual status bar for each workstation.
- Service and validation due-date notifications.
- Remote connection to a selected workstation using the same interface as its panel.
The operator is informed of a remote connection in the status bar.
CONFIGURED FOR YOUR WORKFLOW
Comfort for everyday work.
A spacious work zone, easy-to-clean stainless-steel surfaces and low vibration support focused work. Dimmable LED lighting adapts to your working conditions.
- Electrically height-adjustable stand according to the selected equipment.
- Ergonomic arm support and clearly arranged accessories.
- Reduced mode lowers consumption during breaks while maintaining protective inflow at the front opening. CR2000 controls mode switching.
- Custom equipment and construction adaptations by consultation.
A CLEAR EQUIPMENT OVERVIEW
Standard equipment and options.
We complement the safety cabinet with technologies and accessories to suit your laboratory.
MBB-IVF standard equipment
- Class II biological safety cabinet with HEPA H14 filtration.
- SMART CR2000 touchscreen control system.
- Motorised front-sash movement with position monitoring and optical safety sensors.
- Monitoring of airflow, filter pressure drop and temperature.
- Alarms and traceable audit trail records.
- Dimmable LED lighting and a UV-C lamp.
- Controlled power socket in the work zone.
- Fixed type C stand: frame height 735 mm; working height 800 mm.
- Network connection, remote operation and email / push notifications are included as standard.
- Normal operating and reduced-airflow modes; CTM central timer; front-panel USB connector; residual-current circuit breaker (RCCB).
Optional equipment and custom adaptations
Equipment availability and compatibility are assessed when specifying your MBB-IVF configuration.
Heated surface prepared for microscope integration
Heated work surface and quartz glass for selected, verified complete microscope assemblies. Compatibility is assessed against the LABOX functional specification.
Integrated LCD display
Display in the rear wall of the work zone for viewing information directly while working.
Magnetic instrument holder
Organised storage of suitable metal instruments on the rear wall of the work area.
Height-adjustable stand
Electrically height-adjustable stand: working height 670–1100 mm, available for MBB-IVF-12 and MBB-IVF-18.
Electric work-height adjustment from 67 to 110 cm, with gyroscope-based anti-collision protection that stops movement when an obstacle is detected.
Ergonomic arm support
Height-adjustable arm support across the full width of the workspace.
Camera and image sharing
Webcam in the work zone with streaming to the local network. Share images with patients, students and colleagues.
Connections and utilities
Power, data and USB sockets; utility, gas or vacuum valve according to configuration.
Multipurpose shelf
Shelf below the work surface with an integrated 230 V / 50 Hz power strip for equipment storage and organised connections.
Additional technologies
Ionisation system, anti-vibration elements or integration of customer equipment by consultation.
VOC sensor
Continuous VOC trend monitoring for early indication of changes in workstation air quality.
UPS backup power
Optional uninterruptible power supply to help maintain operation during short mains interruptions. Power rating and backup duration are selected to suit the workstation configuration and connected equipment.
Further modifications and equipment can be added beyond the options listed. We propose suitable solutions according to your laboratory needs and operating safety requirements.

Part of your laboratory monitoring system.
MBB-IVF can be connected to the LBXCON | EMS continuous environmental monitoring system for a central overview, records, alarms and reports. LBXCON | EMS is currently available only in the Czech Republic and Slovakia.
MBB-IVF UP CLOSE
Explore the workstation.
Selected configurations and equipment details. The final arrangement is tailored to your laboratory.


GMP · ISO 14644
Designed for cleanroom use — inside and out.
Our IVF equipment is designed to meet applicable Good Manufacturing Practice (GMP) requirements and the relevant parts of the ISO 14644 series. We consider the work zone as well as the external construction, materials, cleanability and operating functions. The qualification scope is defined for the specific configuration, installation and intended use.
DETAILS TO SUPPORT YOUR CHOICE
Technical information.
Key parameters
| Safety cabinet type | Class II according to EN 12469:2000 |
|---|---|
| Work-zone air cleanliness | ISO Class 5 |
| GMP work-zone grade | Grade A, subject to qualification of the specific configuration and operating conditions |
| Filtration | HEPA H14 |
| Airflow velocity in the work zone | 0.40 ± 0.05 m/s |
| Power supply | 230 V / 50 Hz |
| Heated work surface (depending on configuration) | 600 × 290 mm |
| Electrical power input | MBB-IVF-12: 1245 W MBB-IVF-18: 2075 W |
| Noise emitted to the surroundings | MBB-IVF-12: ~57 dB(A) MBB-IVF-18: ~63 dB(A) The approximate values apply at an airflow velocity of 0.32 m/s. Noise is higher at 0.40 m/s. |
Standard dimensions
| Model | External dimensions W × H × D [mm] | Work zone W × H × D [mm] |
|---|---|---|
| MBB-IVF-12 | 1240 × 1405 × 770 | 1230 × 690 × 560 |
| MBB-IVF-18 | 1850 × 1405 × 770 | 1840 × 690 × 560 |
Cabinet dimensions excluding the stand. The final design is confirmed in the quotation.
Microscope integration — verified assemblies
Verified complete assemblies for MBB-IVF integration. Compatibility applies to the whole configuration, including stand, optics, illumination and camera accessories.
Nikon SMZ1270 · P-DSL32 LED stand
Without camera: SMZ1270 body (1×) · P-B binocular tube (1×) · C-W 10XA-22 eyepiece (2×) · eyeguards (2×) · P-Plan Apo 1× objective, working distance 70 mm (1×) · C-FMCN coarse/fine focusing mount (1×) · P-DSL32 LED transmitted-light stand (1×) · 4-AC AC adapter (1×) · power cord (1×).
With camera: SMZ1270 body (1×) · P-B binocular tube (1×) · C-W 10XA-22 eyepiece (2×) · eyeguards (2×) · P-Plan Apo 1× objective, working distance 70 mm (1×) · C-FMCN coarse/fine focusing mount (1×) · P-DSL32 LED transmitted-light stand (1×) · 4-AC AC adapter (1×) · power cord (1×) · P-IBSS2 beam splitter (1×) · C-0.55X DS relay lens (1×) · BMS 5 MP HDMI camera (1×).
Olympus SZX2-ZB10 · SZX2-ILLTS LED Base
Without camera: SZX2-ZB10 zoom body (1×) · SZX2-LTTR tube (1×) · WHSZ10X-H eyepiece (2×) · SZX2-FOF focusing unit (1×) · DFPLAPO1X-4 objective (1×) · SZX2-ILLTS LED Base (1×) · SZX2-COB cartridge (1×) · U-ACAD4515-1-5 power supply (1×) · UYCP power cord (1×).
With camera: SZX2-ZB10 zoom body (1×) · SZX2-LTTR tube (1×) · WHSZ10X-H eyepiece (2×) · SZX2-FOF focusing unit (1×) · DFPLAPO1X-4 objective (1×) · SZX2-ILLTS LED Base (1×) · SZX2-COB cartridge (1×) · U-ACAD4515-1-5 power supply (1×) · UYCP power cord (1×) · EP50 camera (1×).
Olympus SZX-ZB7 · SZX2-ILLTS LED Base
Without camera: SZX-ZB7 stereomicroscope body (1×) · SZX-AS aperture stop diaphragm (1×) · SZX2-LTTR tube (1×) · WHSZ10X-H eyepiece (2×) · DFPLAPO1X-4 objective (1×) · SZX2-ILLTS LED Base (1×) · SZX2-COB cartridge (1×) · U-ACAD4515-1-5 power supply (1×) · UYCP power cord (1×) · SZ2-STS focusing arm (1×).
With camera: SZX-ZB7 stereomicroscope body (1×) · SZX-AS aperture stop diaphragm (1×) · SZX2-LTTR tube (1×) · WHSZ10X-H eyepiece (2×) · DFPLAPO1X-4 objective (1×) · SZX2-ILLTS LED Base (1×) · SZX2-COB cartridge (1×) · U-ACAD4515-1-5 power supply (1×) · UYCP power cord (1×) · SZ2-STS focusing arm (1×) · EP50 camera (1×).
Request the current LABOX functional specification before ordering. Other assemblies or component substitutions require prior consultation.
Qualification, installation and service
Your local LABOX distributor arranges installation, qualification and service. Please contact your distributor to agree commissioning, qualification testing and ongoing support in your country.
Firmware update options depend on the hardware and software version of the individual unit.
LET'S START WITH YOUR LABORATORY
How should your MBB-IVF be configured?
Your local LABOX distributor will assist with equipment selection, installation, qualification and service. Contact your distributor to discuss your requirements and ongoing support.